Ground-Based Radome Selector Guide
Radome Type: |
Sandwich |
Metal Space Frame |
Solid Laminate |
Dielectric Space Frame |
Typical
|
|
|
|
|
Construction Characteristics* |
Multi-layer construction; doubly-curved polygonal panels bolted together to form truncated sphere. Shell made of highly developed composites for panel consistency and strength. Pre-impregnated fiberglass skins fully enclose each panel core to make panels weather-tight. |
Triangular frames oriented and bolted together to form a geodesic dome. Frames made of metal aluminum extrusion. Proprietary laminate permanently bonded into frames. Other membrane materials available for specific applications. Panel geometries available in both regular and randomized configurations. |
Doubly-curved solid fiberglass panels; thickness depends on radome size and wind speed. Panels arranged in neat vertical and horizontal rows. |
Frames made of pultruded fiberglass beams. Proprietary laminate permanently attached to each beam. Panel geometries available in both regular and randomized configurations. |
Electromagnetic (EM) Performance |
Excellent performance over relatively narrow frequency bands or potentially at multiple discrete frequencies. |
Good performance from 0.5 GHz to 100 GHz with standard membranes. Operational range extended to 1000 GHz with high-performance membranes. |
Excellent performance below 3.0 GHz or at higher frequencies when wall thickness can be tuned for narrow bandwidths. |
Excellent performance below 1.0 GHz with performance nulls at other discrete frequencies. Properly designed tuning can enhance performance. |
Standard Sizes |
10 ft. to 77 ft. (3.0 m to 23.5 m) in diameter. | 6 ft. to 200 ft. (1.8 m to 60.9 m) in diameter. | 42 in. to 18 ft. (1.1 m to 5.5 m) in diameter. | 6 ft. to 68 ft. (1.8 m to 20.7 m) in diameter. |
Advantages |
Skin and core thickness can be varied for optimum performance at operating frequency. Excellent choice if low sidelobes are critical. Good insulation value. Panel assembly and disassembly from inside radome. Easy panel removal for replacement or repair. |
Membrane materials and thickness can be varied for optimum performance at operating frequency. Wide range of sizes, flexibility in design wind speed. Electrostatic cage for lightning protection. Availability of tactical and IMP-free designs. Good EM performance over variety of bands. |
A cost-effective option in smaller sizes. Panel assembly and disassembly from inside radome. |
Wide range of sizes. Excellent EM performance at low frequencies. |
Disadvantages |
Tooling required for each new size. EM performance is frequency-discrete. Manufacturing tolerance critical to achieve desired performance. Joint design critical for effective EM performance. |
Performance at discrete frequency—not as good as sandwich type. Low insulation value unless treated with insulating material. |
Cost increases and performance decreases with size and wind speed. Panels not randomly oriented, allowing for greater boresight and sidelobe degradation. |
Not usually effective over 1.0 GHz. Low insulation value unless treated with insulating material. Larger beams required for structural reasons, thus higher losses than metal space frame type. Not recommended for large radomes. |
* We use preimpregnated fiberglass materials in all ESSCO radomes to help control resin content and thickness.