An X-ray tube is used in the high voltage pulse generator in the basic system configuration. Remote single and dual tubehead operation (options 32 and 35) is available with the purchase of optional equipment. Remote operation protects equipment from damage by fragments or intense shock waves. X-ray tubes that are available in 5mm (standard) (PN: 5081-9551) or 2mm (PN: 5081- 9590). All hardware required for system operation is furnished with the basic system. This includes the control equipment, housed in a 1.8-meter (6 feet) cabinet, the X-ray generator and a 9-meter (30 feet) interconnecting input cable bundle.

Key Features

  • Peak output voltage: 1 MV 
  • Peak current: 6000 A 
  • Dose at 1 m: 55 mR 
  • Dose at 1 m thru 40 mm steel: 5 mR 
  • Standard spot size, X-ray tube: 5 mm 
  • X-ray pulse width (FWHM) 
  • Pulser diameter: 20 in (550 mm) 
  • Pulser length: 55 in (1.4 m) 
  • Pulser weight: 600 lbs (270 kg)

An X-ray Controller (XCON) comes standard and is required for the operation of a flash X-ray system. The XCON contains both a delayed trigger for the X-ray pulser and a pulsed event timer to monitor the actual firing time of the pulser. 

XCON features include: 

  • A firing time delay variable up to 1 second in 10-nanosecond increments 
  • Delay time setting and pulsed event time monitoring can be accomplished locally or with the user’s PC via an Ethernet connection 

Customer furnished equipment is limited to: 

  • Regulated compressed dry air and regulated sulfur hexafluoride (SF6) 
  • AC power (120 Vac, 60 hertz standard) 
  • Up to three additional 1 megavolt X-ray generators, (option 001) may share the same control cabinet and power supply to minimize cost and floor space 
  • Option 008 permits operation at a 220 Vac, 50-60 Hz line voltage

 

SYSTEM SELECTION
SystemFTSDPenetration in ALPenetration in Steel
150 kV10 ft0.1 inN/R
300 kV Single10 ft1.2 in0.2 in
300 kV Dual10 ft0.7 in0.1 in
450 kV Single10 ft2.7 in0.6 in
450 kV Dual10 ft1.7 in0.4 in
450 kV Super10 ft3.2 in1.0 in
1 MV10 ft4.0 in1.4 in
1 MV Super10 ft5.2 in1.8 in

Channels and Options

SINGLE CHANNEL SYSTEM (STAND ALONE SYSTEM)

Control console cabinet 

  • AC power panel with surge protector 
  • High voltage power supply 
  • Dielectric gas pressurization controls 
  • XCON (X-ray controller)
Trigger transformer
Trigger pendant
FXR pulser
9 m (30 ft) control cable and air line bundle
X-ray tube
Resistive load
ADD-ON CHANNEL
XCON (X-ray controller)
Trigger transformer
FXR pulser
9 m (30 ft) control cable and air line bundle
X-ray tube
Resistive load
OPTIONS
001Add-on 1MV channel
008220 Vac, 60-60 Hz Operation
020Added length console-to-pulser cable
032Single remote tubehead
034Added length tubehead cable
035Dual remote tube heads
SpecialDemountable tube with variable source size – contact factory