150kV Cine Radiographic System

Overview

The system is designed to provide up to six sequential images, with each image being timed by the user to be 3 to 1000 microseconds apart. With the power of the PixelRay™ Command Control and Analysis Software, the user can capture, calibrate and precisely measure the image information. The system is modular and can be used with single frame cameras, multi frame cameras or CR Imaging.

X-ray generators6 each - 150 kV Pulsers (Model 43731)
X-ray head6-channel Cine demountable pumped X-ray head
Spot size0.5 mm, 1 mm or 3 mm (nominal)
X-ray source diameter~1.5 in
Dose2.5 mR per pulse at 1 m
Inter-pulse time3 to 1000 ms
Exposure time (pulse width)70 x 10-9 sec
Source cart assembly size37 in W x 60 in D x 65 in H
System control rack size24 in W x 32 in D x 8 in H
High-voltage power supply (#130-314700) 
XCON (6 each all-in-one X-ray controller #43120B)Delay trigger generator, trigger amplifier, pulsed event timer
Vacuum pump and controller 
Electrical power (including cameras)120 V, 20 A
All system interconnecting and control cables included
  • 6 each 150 kV pulsers (Model 43731) 
  • X-ray control console (remote control optional) 
  • 6-channel demountable pumped X-ray head 
  • X-ray source service cart 
  • Vacuum pump > Pump controller 
  • All connecting cables 
  • 6 each CCD cameras (option 1) or 3 each intensified cameras (option 2) 
  • 6 each 55 mm 1.2 lenses 
  • Mirror adjustment assembly 
  • Fiber-optic communication bundle 
  • Shielded camera housing mounted on adjustable service cart 
  • Integrated communication 
  • System camera control software
Camera Option 1

Camera Option 1

Camera Option 2

Camera Option 2

 Camera option 1Camera Option 2
Frame rate1 ms< 100 ns
Spatial resolution1376 x 1040 px1360 x 1024 px at 12 bits
Quantum efficiency1376 x 1040 px

38% @390 nm (HSS1), 

62% @ 500 nm (GOS:Pr)

Low readout noise2.4 counts/px6/px = 1.2 counts/px
Pixel binning2x2, 4x4, 8x82x2, 4x4, 8x8
Camera Communication and Control (Software Included)
 Camera option 1Camera option 2
High-resolution CCD6 each3 each
55 mm 1.2 Camera lenses6 each3 each
Fiber-optic communication bundle6 each3 each

Digital Image Size

Screen sizeScan speedFile size
14 in by 17 in100 µm30 MB
14 in by 17 in50 µm120 MB
14 in by 51 in50 µm360 MB

Dose per Pulse Filtration

FILTERED X-RAY DOSE DATA

Step wedge data

AL AND CU STEP WEDGE DATA

X-Ray Dose at 1 meter
Scintillator light decay
Cumulative Scintillator Light

X-ray dose per pulse depends upon filtration. Typically 0.5” HDPE for blast shield. Cine system gives higher dose for low filtration due to window differences: Cine 0.032” Al vs. standard FXR 0.003” Slope of step wedge data shows both sources have similar penetration and endpoint HSS1 99% of integrated light output within 4 ms < 0.1% ghost after 5 ms GOS:Pr High-Pr (2%) is marginal for 5-ms frames, good for >10-ms framing 90% of integrated light output within 5 ms, 99% within 10 ms Low-Pr (0.07).

Resources

  • FXR 150KV Cine Radiography System

    150kV Cine Radiographic System Data Sheet